Having problems with your Refrigerators ?

Gdm-87 fan makes noises at times and won't start. I can get it going and fridge cools fine but once fan shuts off during cycle it won't start back on its own and compressor shuts itself down.


Answers :

Sounds like the fan is dirty and needs removal,while it is out of the unit clean out all the condenser coil area and upon replacing the fan unit,also replace the overload ptc relay on the compressor body in the lower rear area as this is weak too and part of your problems too

Repair Help & Product Troubleshooting for Refrigerators
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Gdm-87 fan makes noises at times and won't start. I can get it going and fridge cools fine but once fan shuts off during cycle it won't start back on its own and compressor shuts itself down.


Sounds like the fan is dirty and needs removal,while it is out of the unit clean out all the condenser coil area and upon replacing the fan unit,also replace the overload ptc relay on the compressor body in the lower rear area as this is weak too and ... True Refrigerators

Checked unit found ref indicator light on steady found some what dirty filter. cleaned filter restarted unit water pump came on then compressor started but only ran for about 2 min then tripped out. condenser fan ran for a bit then shut off. After a bit the fan came back on but no compressor. Finally when the compressor tried to start the over load just tripped on compressor. I'm thinking compressor is either getting to much back pressure or is tripping out on over load,tight compressor any thau


... Scotsman Ice Machine - 290lb Self-Contained Air-Cooled Cuber - SCE275A-1H

This is a old problem with maytag refrigerator, coil icing over I have changed the t'stat heating element assy,coil still ice over All fans are working, i removed adaptive defrost board and found it to be burnted by some resistors and I replaced with the substitute board (#61005899) but whe i turn on my temperature control nothing happens compressor will not start, so I install old burnt board and compressor starts it just wont activate the defrost cycle but ill do it if i jump it out by jumpi


Looks like the adaptive defrost board is a problem. The question is whether you had the correct replacement part. Best to confirm if the part shown ... Refrigerators

Refridgerator buzzing noise when compressor turns on i have a whirlpool refridgerator & everytime the compressor starts. it starts making noise. in the refridgerator is still cold but to make the noise stop, we turn down the temperature & then turn it back up. but now, the noise wont stop unless we turn the refridgerator all the way to zero when the fan is on. i dont want to turn it off. what do i do?


IF THE BUZZING SOUND IS ONLY THERE WHEN THE MOTOR IS RUNNING THAT COULD MEAN ONLY ONE THING.YOUR PISTON IN SIDE THE COMPRESSOR IS NOISEY THE ONLY WAY TO SOLVE THAT IS TO REPLACE THE COMPRESSOR.BEST YOU HAVE A TECH TO ADVICE YOU FUTHER.GOODLUCK.MOHAME ... Whirlpool ED2FHEXN Side by Side Refrigerator

The compressor wont start back up. The fan runs


Unplug. Then feel the compressor by hand. Is the shell really hot? go get some ice and cool it off or leave unplug for a day. after cool off re-plug to see if compressor kicks back on. if it does make sure it is clean inderneath otherwaise it will ... Refrigerators

The compressor wont start back up. The fan runs


Check the start relay and klixon, these may be burnt out. ... Refrigerators

Refridge would cycle on, fan would come on relay would click but no compressor. relay kept clicking no compressor. I changed relay and capacitor on compressor plugged in all went well. after a few hours temps came down made ice fine fridge temp good. when it cycled off it cycled back on after awhile. Fan came on relay clicked but no compressor. Same problem. On a hunch I unplugged power line plugged back in and fan and compressor came on as they should Help would be appreciated. Frank.


You were lucky . compressor must run with fan or it will get too hot . if comp is running to hot it will not come on and the fan will . . do you have the cardboard back on frig . this helps direct air to cool comp .. reck ... Maytag 25.6 cu. ft. Wide-By-Side Refrigerator with PuriClean II Ice and Water

N'finity 170 bottleis dual bottle zone wine refrigerator. Unit will begin cycle when turn off and on. Gets down to set temp and will cycle correctly maybe 2 times and then temp will slowly rise. Unit will not start to cycle and cool until I shut off and then turn back on. Fans seem to be running all day. What can be the problem?


Hi, there are some little thermal switches, and or 2 fans that may not be working properly. In both cases they are not cooling the unit down enough for it to maintain the set temperature. This unit is pretty much low grade, high cost, JUNK. Your mino ... Refrigerators

Noticed a sound from my Kenmore 106.41512101 refrigerator. It was a buzzing sound that lasted about 12 seconds and then shut off for 2 minutes or so and then start buzzing again. This was an endless cycle. Aslo discovered the fridge and freezer temps were rising. I then pulled out the fridge from the wall and removed the lower cover. Discovered the sound was coming from the compressor area. The compressor was also very hot. The fan was also constantly running. I thought there may have been a ba


Hello,You will need to test the compressor on your device to know if it is still good, follow the procedure below to test if your compressor is still good.At the bottom rear of the refrigerator you will see a large cylindrical ... Refrigerators

I have a kenmore frig 10653502300 cooling is fine all fans and compressor works. but when cooling cycle is to start neither compressor , condensing fan, or evaporation fan comes on, until either door is closed and seemingly the jolt of the door begins the cycle, i need a electrical schematic to determine which component is common to all three on start up. thanks [email protected]


\015\012The diagram above is the electrical wiring circuit schematics of kenmore frig 10653502300/ kenmore ... Kenmore Refrigerators

I have a Kitchen Aid side by side , model # KSRD22FTST03. The fan in the freezer compartment runs all the time and I noticed frost build up on the back panel and in particular in the vent at the bottom of the freezer. Also, the water filter light blinks green all the time. So far the temps are good in both the freezer and fridge boxes. I also started noticing a loud rumbling sound sometimes just before the compressor shuts off. Maybe for 10-15 seconds. Thanks for your help


... Refrigerators

I have a upright freezer that the compressor wont kick in and start, i can hear it click and try but then clicks back off, the fan runs because i can feel air inside the freezer but not cold air


Hi,\015\012The clicking that you are hearing is the compressor trying to start and then shutting down when the overload kicks back off. \015\012The compressor is either siezed up or the motor has failed. Either way it will need to be repl ... Refrigerators

I have a may tag MBB 2254 G /2256 G refrigerator. The machine was not cooling, pulled the back and front panels and vacuumed out, full of dust, lint etc. I plugged back in, let go for a hour or so, a little cooling but not much. The compressor seemed fairly hot. I could hear the relay cycling I assume to kick the compressor. After several seconds hear another relay click. I do not feel any coldness on the compressor copper lines. The back fan is running, the interior fan is circulating.


... Maytag MBB2256GES Bottom Freezer Refrigerator

Yesterday I came home and noticed my ice in the ice maker was melting. I pulled the back panel off and found the fan blade that cools the condensor was off so I put it back on. Today I get home and the frig/freezer is still not working. I hear the compressor trying to start, but after roughly 10 seconds it "clicks" and goes back on standby for a period of time and then trys to start again. Is it possibble it could be the capacitor or whatever it is called on the side of the compressor, or is it


This normally could be a bad start relay(most likely to fail and cheapest to replace) and over load for the compressor, dirty condenser coils need cleaning, condenser fan motor is not running or the compressor itself which may have overheated if the ... Refrigerators

The compressor will run at times, but the condenser fan doesn't start and the unit shuts off on either high pressure or the compressor overheats. Why doesn't the fan start with the compressor? The unit is less than a year old and it has done this since it was new. It may work for a month or two, but eventually it does it again.


IF UIT IS A YEAR OR LESS OLD YOU ARE BETTER OFF CONTACTING THE MANUFACTURER, SINCE THE UNIT HAS WARRANTY FOR PARTS AND LABOR DURING THE FIRST YEAR THEY WILL COVER ALLSO THE FREIGHT COST.CALL THEM 858-566-7473 ... Breezaire WKE 6000 Wine Cooler

Have some problem with Frigidaire FRS26ZGG, when turned on compressor start correctly and after 15 min shut off everything even both fans, exept lights inside, turned off for few hours and turned on again, start correctrnafter 15- 20 min shut off and not started. Checked start relay and capacitor. Turn on again, but after 15min shut off again automatically


... Frigidaire Refrigerators

I have a 25 cubic ft Amana Side by side,the compressor tries to start but wont,also the evaporator fan wont run, does the compressor have to bre running for the fan to work?


Check amp draw on compressor wires. is the evap coil froze up ? ... Refrigerators

I have a frigidare model FRS23Kr4awo that seems to have stopped working. I can hear the compressor come on in the back but the fan inside never comes on. I have tried turning the automatic thermostat and it cycles off but when the compressor comes on the fans in the back and inside don't run. TAny ideas?


... Frigidaire FRS23KR4AW Side by Side Refrigerator

I have a norcold MRFT-60 portable refrigerator. When I plug it in, the compressor cycles on for about 3 seconds, then off, back on for 3 sec, and keeps repeating. I have it on 115v ac, the sawafuji compressor reads 12v ac. Is the compressor bad? or electrical? The cooling fan cycles with the compressor, after a while the compressor gets warm,but unit still won't cool. I can not find any info on these. I have 3 of them, one Engel, 2 Norcolds. The others come on and cool instantly while the compre


... Thetford Norcold RV Cooler/Freezer

The compressor will not stay on. Will not stay cold. Every few minutes you hear a click and the compressor will kick on but about 6 seconds later it clicks again and shuts off. The fan continuously runs. We Cleaned all dust and coils. Nothing is hot in the back(coils,compressor etc) and there is no condensation back there either. Do you think this a bad relay switch or something more serious like the compressor needing replacement. Thanks


If it was my fridge in your place i'd try and replace the comp start device first and if that does not work you will prob need a new comp.try this website: ... Whirlpool ED5LHAXWB 25 cu. ft. side-by-side refrigerator with in-door

I have a GE refrigerator (model # GSH25SGRESS). The problem happens when the compressor needs to kick back on I hear a clicking noise from the main control panel but the compressor doesn’t start up. It seems that when I activate the water dispenser the compressor will start up again. I also noticed that both the water and ice dispenser do not always work and when they don’t, I try again later and they will usually work. The compressor shut-off when it reaches the refrigerator’s cooler set


Change the control. GE has a number of problems with the original boards. ... GE (PSS26MSRSS) Side by Side Refrigerator

I have a samsung rs2555sl side by side - fridge nor freezer is getting cold. what i know: 1.cleaned coils in back with vacuum, 2. fan is blowing on (hot)compressor, but no noise is coming from compressor, 3. every few minutesthere's a clicking noise coming from the back near the compressor followed by a very low hum?, as if it's supposed to start something(i don't know) . freezer temp on front of door has been 70 F for the past hour. don't know if cleaning the coils were the issue...


See http://www.fixya.com/support/t1191678-samsung_rs2555sl_not_cooling_compressor ... Samsung 24.8 Cu. Ft. Side-by-Side Refrigerator with Thru-the-Door Ice and Water - Stainless-Platinum... Side by Side Refrigerator

The freezer is only cooling to 20 degrees. It is maintaining 20. Started two days ago. The compressor is running continuous. If I tuen the thermostat down, the compressor will cut off. But only on the lowest setting. When I turn it back to factor setting, the compressor cuts back on and runs. The fan is working and moving air


Hi, Many times a freezer and/or refrigerator do not work right because of a dirty condenser coil...there are also many other things that can go wrong. \012 \012If you are heari ... Kenmore Refrigerators

My fridge clicking, buzzing and then clicking back off. Inside it was starting to warm up and was starting to leak water onto the floor. Today someone came out and replaced the relay. After 4 hours the freezer is down to 30 degrees but the refrigerated section is only 58 degrees. It does not sound like the fans are functioning and there is frost starting to accumulate on the back panel of the freezer. My fridge is an 8 year old Maytag. Is the compressor bad or is it something else?


Hello, no if the compressor is still running and you are not hearing the click you should be ok. It will take approx 8-10 hours for it to get to normal temp. The frost you mention on the freezer panel could be a problem with the defrost system. I wou ... Maytag Refrigerators

My compressor cooling fan quit- the compressor still runs. I unplugged the unit then plugged it back in. The cooling fan ran for about 15 seconds, then shut off again. Is the problem with the main control circuit board or with the compressor control board?.....


The problem is most likely the condensor fan motor is starting to fail. This is easy to check, First remove the back cover and when the compressor is running you should have voltage going to the fan motor if you do the fan motor needs replacing if no ... KitchenAid Superba Architect KSCS25INSS Side by Side Refrigerator